sigc::mem_fun (*_rc_config, &RCConfiguration::set_meter_line_up_level)
);
- mlu->add (MeteringLineUp24, _("-24dBFS"));
- mlu->add (MeteringLineUp20, _("-20dBFS (SMPTE)"));
+ mlu->add (MeteringLineUp24, _("-24dBFS (SMPTE US: 4dBu = -20dBFS)"));
+ mlu->add (MeteringLineUp20, _("-20dBFS (SMPTE RP.0155)"));
mlu->add (MeteringLineUp18, _("-18dBFS (EBU, BBC)"));
mlu->add (MeteringLineUp15, _("-15dBFS (DIN)"));
- Gtkmm2ext::UI::instance()->set_tip (mlu->tip_widget(), _("Configure meter-ticks and color-knee point for dBFS scale DPM, set reference/offset level for IEC PPM."));
+ Gtkmm2ext::UI::instance()->set_tip (mlu->tip_widget(), _("Configure meter-marks and color-knee point for dBFS scale DPM, set reference level for IEC1/Nordic, IEC2 PPM and VU meter."));
add_option (S_("Preferences|GUI"), mlu);
+ ComboOption<MeterLineUp>* mld = new ComboOption<MeterLineUp> (
+ "meter-line-up-din",
+ _("IEC1/DIN Meter line-up level; 0dBu"),
+ sigc::mem_fun (*_rc_config, &RCConfiguration::get_meter_line_up_din),
+ sigc::mem_fun (*_rc_config, &RCConfiguration::set_meter_line_up_din)
+ );
+
+ mld->add (MeteringLineUp24, _("-24dBFS (SMPTE US: 4dBu = -20dBFS)"));
+ mld->add (MeteringLineUp20, _("-20dBFS (SMPTE RP.0155)"));
+ mld->add (MeteringLineUp18, _("-18dBFS (EBU, BBC)"));
+ mld->add (MeteringLineUp15, _("-15dBFS (DIN)"));
+
+ Gtkmm2ext::UI::instance()->set_tip (mld->tip_widget(), _("Reference level for IEC1/DIN meter."));
+
+ add_option (S_("Preferences|GUI"), mld);
ComboOption<VUMeterStandard>* mvu = new ComboOption<VUMeterStandard> (
"meter-vu-standard",
sigc::mem_fun (*_rc_config, &RCConfiguration::set_meter_vu_standard)
);
- mvu->add (MeteringVUfrench, _("+2dB (France)"));
- mvu->add (MeteringVUamerican, _(" 0dB (North America, Australia)"));
- mvu->add (MeteringVUstandard, _("-4dB (standard)"));
+ mvu->add (MeteringVUfrench, _("0VU = -2dBu (France)"));
+ mvu->add (MeteringVUamerican, _("0VU = 0dBu (North America, Australia)"));
+ mvu->add (MeteringVUstandard, _("0VU = +4dBu (standard)"));
+ mvu->add (MeteringVUeight, _("0VU = +8dBu"));
add_option (S_("Preferences|GUI"), mvu);
_("Specify the audio signal level in dbFS at and above which the meter-peak indicator will flash red."));
add_option (S_("Preferences|GUI"), mpks);
+
+ add_option (S_("Preferences|GUI"),
+ new BoolOption (
+ "meter-style-led",
+ _("LED meter style"),
+ sigc::mem_fun (*_rc_config, &RCConfiguration::get_meter_style_led),
+ sigc::mem_fun (*_rc_config, &RCConfiguration::set_meter_style_led)
+ ));
+
}
void