c[7] = c[8] = c[9] = c[6];
break;
case MeterPeak0dB:
- stp[1] = 115.0 * log_meter0dB(-10);
- stp[2] = 115.0 * log_meter0dB(-3);
- stp[3] = 115.0 * log_meter0dB(0);
+ stp[1] = 89.125; // 115.0 * log_meter0dB(-9);
+ stp[2] = 106.375; // 115.0 * log_meter0dB(-3);
+ stp[3] = 115.0; // 115.0 * log_meter0dB(0);
switch (ARDOUR_UI::config()->get_meter_line_up_level()) {
case MeteringLineUp24:
stp[0] = 115.0 * log_meter0dB(-24);
}
break;
default: // PEAK, RMS
- stp[1] = 77.5; // 115 * log_meter(-10)
+ stp[1] = 77.5; // 115 * log_meter(-9)
stp[2] = 92.5; // 115 * log_meter(-3)
stp[3] = 100.0; // 115 * log_meter(0)
switch (ARDOUR_UI::config()->get_meter_line_up_level()) {