Mixbus: auto-connect monitor-section
authorRobin Gareus <robin@gareus.org>
Wed, 20 Apr 2016 14:17:22 +0000 (16:17 +0200)
committerRobin Gareus <robin@gareus.org>
Wed, 20 Apr 2016 14:17:22 +0000 (16:17 +0200)
Mixbus does not expose the "auto_connect_standard_busses" preference
and forces it to false.

libs/ardour/session.cc

index d1647d3ee1d12f2be202991d328ea481edc707fb..1fcd219e95976b657a88bf20749e5999f57c8dbf 100644 (file)
@@ -1140,7 +1140,7 @@ Session::add_monitor_section ()
        /* if monitor section is not connected, connect it to physical outs
         */
 
-       if (Config->get_auto_connect_standard_busses() && !_monitor_out->output()->connected ()) {
+       if ((Config->get_auto_connect_standard_busses () || Profile->get_mixbus ()) && !_monitor_out->output()->connected ()) {
 
                if (!Config->get_monitor_bus_preferred_bundle().empty()) {