revert functionality of f842e8af2 (meter display in DISK mode)
authorRobin Gareus <robin@gareus.org>
Tue, 16 Jul 2013 19:18:52 +0000 (21:18 +0200)
committerPaul Davis <paul@linuxaudiosystems.com>
Thu, 8 Aug 2013 19:23:10 +0000 (15:23 -0400)
libs/ardour/track.cc

index e8eea740b1ff7763af5c8e1ddf35f6cb21de08df..522b9ebe056552f9e7e1e96bae6aaa4fd5ed289b 100644 (file)
@@ -416,10 +416,7 @@ Track::no_roll (pframes_t nframes, framepos_t start_frame, framepos_t end_frame,
                        bool const tape_machine_mode = Config->get_tape_machine_mode ();
                        bool no_meter = false;
 
-                       if (_monitoring & MonitorDisk && !track_rec) {
-                               no_meter=true;
-                       }
-                       else if (!software_monitor && tape_machine_mode && !track_rec) {
+                       if (!software_monitor && tape_machine_mode && !track_rec) {
                                no_meter=true;
                        }
                        else if (!software_monitor && !tape_machine_mode && !track_rec && !auto_input) {